7883A

CAT6 Patch, 4pr, UTP, PVC Jkt, CMR

...
CAT6 (250MHz), 4-Pair, U/UTP-unshielded, Riser-CMR, Premise Patch cable, 24 AWG solid bare copper conductors, polyolefin insulation, central filler, PVC jacket, RG-45 compatible
Get Product Alerts

Specifications
Product Overview

Suitable Applications

Premise Patch Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM

Physical Characteristics (Overall)
Conductor
AWG Stranding Material No. of Pairs
24 Solid BC - Bare Copper 4

Conductor Count

8

Total Number of Pairs

4

Insulation
Material
PO - Polyolefin

Bonded-Pair

N/A

Color Chart
Number Color
1 White/Blue Stripe & Blue
2 White/Orange Stripe & Orange
3 White/Green Stripe & Green
4 White/Brown Stripe & Brown
Outer Jacket
Material Nominal Diameter Ripcord Separator Material
PVC - Polyvinyl Chloride 0.205 in No Central Filler
Electrical Characteristics
Conductor DCR
Max. Conductor DCR Max. DCR Unbalance
93.8 Ohm/km 5 %
Capacitance
Max. Capacitance Unbalance Nom.Mutual Capacitance
160 pF/100m 15 pF/ft
Delay
Frequency [MHz] Max. Delay Max. Delay Skew Nominal Velocity of Propagation (VP) [%]
100 MHz 537.6 ns/100m 45 ns/100m 70%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation) Min. NEXT [dB] Min. PSNEXT [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Max./Min. Input Impedance (unFitted) Max./Min. Fitted Impedance Min. TCL [dB] Min. ELTCTL [dB]
1 MHz 2.4 dB/100m 74.3 dB 72.3 dB 67.8 dB 64.8 dB 20.0 dB 100 ± 15 Ohm 100 ± 15 Ohm 40.0 dB 35.0 dB
4 MHz 4.5 dB/100m 65.3 dB 63.3 dB 55.8 dB 52.7 dB 23.0 dB 100 ± 15 Ohm 100 ± 15 Ohm 40.0 dB 23.0 dB
8 MHz 6.4 dB/100m 60.8 dB 58.8 dB 49.7 dB 46.7 dB 24.5 dB 100 ± 15 Ohm 100 ± 15 Ohm 40.0 dB 16.9 dB
10 MHz 7.1 dB/100m 59.3 dB 57.3 dB 47.8 dB 44.8 dB 25.0 dB 100 ± 15 Ohm 100 ± 15 Ohm 40.0 dB 15.0 dB
16 MHz 9.1 dB/100m 56.2 dB 54.3 dB 43.7 dB 40.7 dB 25.0 dB 100 ± 15 Ohm 100 ± 15 Ohm 38.0 dB 10.9 dB
20 MHz 10.2 dB/100m 54.8 dB 52.8 dB 41.8 dB 38.8 dB 25.0 dB 100 ± 15 Ohm 100 ± 15 Ohm 37.0 dB 9.0 dB
25 MHz 11.4 dB/100m 53.3 dB 51.3 dB 39.8 dB 36.8 dB 24.3 dB 100 ± 15 Ohm 100 ± 15 Ohm 36.0 dB 7.0 dB
31.25 MHz 12.8 dB/100m 51.9 dB 49.9 dB 37.9 dB 34.9 dB 23.6 dB 100 ± 15 Ohm 100 ± 15 Ohm 35.1 dB 5.1 dB
62.5 MHz 18.5 dB/100m 47.4 dB 45.4 dB 31.9 dB 28.9 dB 21.5 dB 100 ± 15 Ohm 100 ± 15 Ohm 32.0 dB
100 MHz 23.8 dB/100m 44.3 dB 42.3 dB 27.8 dB 24.8 dB 20.1 dB 100 ± 15 Ohm 100 ± 15 Ohm 30.0 dB
155 MHz 30.2 dB/100m 41.5 dB 39.5 dB 23.9 dB 20.9 dB 18.8 dB 100 ± 22 Ohm 100 ± 15 Ohm 28.1 dB
200 MHz 34.8 dB/100m 39.8 dB 37.8 dB 21.8 dB 18.8 dB 18.0 dB 100 ± 22 Ohm 100 ± 15 Ohm 27.0 dB
250 MHz 39.4 dB/100m 38.3 dB 36.3 dB 19.8 dB 16.8 dB 17.3 dB 100 ± 32 Ohm 100 ± 15 Ohm 26.0 dB

Segregation class according EN50174-2

a

Voltage
UL Voltage Rating
300 V RMS
Temperature Range

Installation Temperature Range

0°C To +50°C

UL Temp Rating

75°C

Storage Temperature Range

-20°C To +75°C

Operating Temperature Range

-20°C To +75°C

Mechanical Characteristics

Bulk Cable Weight

20 lbs/1000ft

Max. Pull Tension

25 lbs

Min. Bend Radius During Installation

2.25 in

Min. Bend Radius/Minor Axis

1.0 in

Standards

NEC/(UL) Compliance

CMR

CEC/C(UL) Compliance

CMR

ISO/IEC Compliance

11801 ed 2.2 (2011) Class E Patch

CPR Euroclass

Eca

Data Category

Category 6

ANSI Compliance

S-116-732-2013 Category 6 Patch, ANSI/NEMA WC-66 Category 6 Patch

TIA/EIA Compliance

ANSI/TIA-568-C.2 Category 6 Patch

IEEE Compliance

IEEE 802.3bt Type 1, Type 2, Type 3, Type 4

Third Party Performance Verification

Category 6 Patch

Applicable Environmental and Other Programs

Environmental Space

Riser

EU Directive 2000/53/EC (ELV)

Yes

EU Directive 2003/11/EC (BFR)

Yes

EU Directive 2003/96/EC (BFR)

Yes

EU Directive 2011/65/EU (RoHS 2)

Yes

EU Directive 2012/19/EU (WEEE)

Yes

EU Directive 2015/863/EU (RoHS 2 amendment)

Yes

EU Directive Compliance

Yes

EU CE Mark

Yes

EU REACH SVHC Compliance (yyyy-mm-dd)

2017-07-10

MII Order #39 (China RoHS)

Yes

Suitability

Suitability - Aerial

No

Suitability - Burial

No

Suitability - Hazardous Locations

No

Suitability - Indoor

Yes

Suitability - Non-Halogenated

No

Suitability - Oil Resistance

No

Suitability - Outdoor

No

Suitability - Sunlight Resistance

No

Flammability, LS0H, Toxicity Testing

CSA/C(UL) Flammability

FT4

UL Flammability

UL 1666 Riser

IEC Flammability

IEC 60332-1-2

UL voltage rating

300 V RMS

Plenum/Non-Plenum

Plenum (Y/N)

No

Product Notes

Footnote

C - CRATE REEL PUT-UP.

Notes

Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage Markings.

History

Update and Revision

Revision Number: 0.512 Revision Date: 12-12-2023

Part Numbers
Item # Color Put-Up Type Length UPC
7883A 0101000 Black Reel 1,000 ft 612825190660
7883A 0101000 Black Reel 1,000 ft 612825190660
7883A 0061000 Blue Reel 1,000 ft 612825190639
7883A 0061000 Blue Reel 1,000 ft 612825190639
7883A F2V1000 Gray Reel 1,000 ft 612825190585
7883A F2V1000 Gray Reel 1,000 ft 612825190585
7883A 0051000 Green Reel 1,000 ft 612825190622
7883A 0051000 Green Reel 1,000 ft 612825190622
7883A 0031000 Orange Reel 1,000 ft 612825190608
7883A 0031000 Orange Reel 1,000 ft 612825190608
7883A 0071000 Purple Reel 1,000 ft 612825190646
7883A 0071000 Purple Reel 1,000 ft 612825190646
7883A 0021000 Red Reel 1,000 ft 612825190592
7883A 0021000 Red Reel 1,000 ft 612825190592
7883A 0091000 White Reel 1,000 ft 612825190653
7883A 0091000 White Reel 1,000 ft 612825190653
7883A 0041000 Yellow Reel 1,000 ft 612825190615
7883A 0041000 Yellow Reel 1,000 ft 612825190615