2149A

Category 6 Indoor/Outdoor Cable, 4 Pair, F/UTP, CMR/CMX

...
Category 6+ Premise Horizontal Cable (350MHz), Indoor/Outdoor, 4 Pair, 23 AWG Solid Bare Copper Conductors, F/UTP - Foil Shielded, Riser-CMR/CMX Outdoor, PVC Jacket
Get Product Alerts

Specifications
Product Overview

Suitable Applications

Indoor/Outdoor, Premise Horizontal Cable, Ethernet 1000BASE-T, Ethernet 100BASE-TX, Ethernet 10BASE-T, PoE++, PoE+, PoE, Noisy Environments

Patent

This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/patents.

Construction Details
Conductor
Size Stranding Material No. of Pairs
23 AWG Solid BC - Bare Copper 4
Insulation
Material Color Code
PO+FEP - Polyolefin + Fluorinated Ethylene Propylene White/Blue Stripe and Blue, White/Orange Stripe and Orange, White/Green Stripe and Green, White/Brown Stripe and Brown
Outer Shield
Shield Type Material Coverage Drainwire Type
Tape Polyester + Bi-Laminate (Alum+Poly) 100% 24 AWG (Solid) TC
Outer Jacket
Separator Material Nom. Diameter Ripcord
Center Member (Patented X-Spline®) PVC - Polyvinyl Chloride 0.296 in (7.52 mm) No

Overall Cable Diameter (Nominal)

0.296 in (7.52 mm)

Electrical Characteristics
Electricals
Max. Conductor DCR Max. Capacitance Unbalance
93.8 Ohm/km (28.6 Ohm/1000ft) 330 pF/100m
Delay
Frequency Max. Delay Max. Delay Skew Nom. Velocity of Prop.
100 MHz 537.6 ns/100m 45 ns/100m 68%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation) Min. NEXT [dB] Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Max./Min. Input Impedance (unFitted) [Ohm] Min. TCL [dB] Min. ELTCTL [dB]
0.772 1.8 dB/100m 77.0 77.0 75.2 76.2 73.0 70.0 19.4 100 +/- 15 40.0 37.2
1 2.0 dB/100m 75.3 75.3 73.3 74.3 70.8 67.8 20.0 100 +/- 15 40.0 35.0
4 3.7 dB/100m 66.3 66.3 62.6 63.6 58.8 55.8 23.0 100 +/- 15 40.0 23.0
8 5.2 dB/100m 61.8 61.8 56.6 57.6 52.7 49.7 24.5 100 +/- 15 40.0 16.9
10 5.8 dB/100m 60.3 60.3 54.5 55.5 50.8 47.8 25.0 100 +/- 15 40.0 15.0
16 7.4 dB/100m 57.2 57.2 49.9 50.9 46.7 43.7 25.0 100 +/- 15 38.0 10.9
20 8.3 dB/100m 55.8 55.8 47.5 48.5 44.8 41.8 25.0 100 +/- 15 37.0 9.0
25 9.3 dB/100m 54.3 54.3 45.1 46.1 42.8 39.8 24.3 100 +/- 15 36.0 7.0
31.25 10.4 dB/100m 52.9 52.9 42.5 43.5 40.9 37.9 23.6 100 +/- 15 35.1 5.1
62.5 15.0 dB/100m 48.4 48.4 33.4 34.4 34.9 31.9 21.5 100 +/- 15 32.0
100 19.3 dB/100m 45.3 45.3 26.0 27.0 30.8 27.8 20.1 100 +/- 15 30.0
155 24.6 dB/100m 42.4 42.4 17.9 18.9 27.0 24.0 19.5 100 +/- 22 28.1
200 28.3 dB/100m 40.8 40.8 12.5 13.5 24.8 21.8 18.7 100 +/- 22 27.0
250 32.1 dB/100m 39.3 39.3 7.2 8.2 22.8 19.8 18.0 100 +/- 32 26.0
300 35.6 dB/100m 38.1 36.1 2.5 1.5 21.3 18.3 17.5 100 +/- 32 25.2
350 38.9 dB/100m 37.1 35.1 19.9 16.9 17.0 100 +/- 32 24.6
400 42.0 dB/100m 36.3 34.3 18.8 15.8 16.6 100 +/- 32 24.0
450 45.0 dB/100m 35.5 33.5 17.7 14.7 16.2 100 +/- 32 23.5
500 47.9 dB/100m 34.8 32.8 16.8 13.8 15.9 100 +/- 32 23.0
550 50.6 dB/100m 34.2 32.2 16.0 13.0 15.6 100 +/- 32 22.6
Voltage
UL Voltage Rating
300 V (CMR), 300 V (CMX-Outdoor)
Mechanical Characteristics
Temperature
UL Temperature Operating Installation Storage
90°C -40°C To +75°C -20°C To +75°C -40°C To +75°C
Bend Radius
Stationary Min. Installation Min.
2.5 in (64 mm) 3.0 in (76 mm)

Max. Pull Tension

25 lbs (11 kg)

Bulk Cable Weight

41 lbs/1000ft

Standards and Compliance

Environmental Suitability

Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance, Aerial - When supported by messenger wire

Flammability / Reaction to Fire

UL 1666 Riser, FT4, IEEE 1202 Vertical Tray Flame Test, IEC 60332-1-2

CPR Compliance

CPR Euroclass: Eca; CPR UKCA Class: Eca

NEC / UL Compliance

Article 800, CMR, CMX-Outdoor, CMG

CEC / C(UL) Compliance

CMX-Outdoor;CMG

ICEA Compliance

S-116-732, S-56-434, S-99-689, S-100-685

IEEE Compliance

IEEE 802.3bt Type 1, Type 2, Type 3, Type 4

NEMA Compliance

ANSI/NEMA WC-66

Data Category

Category 6

TIA/EIA Compliance

ANSI/TIA-568.2-D Category 6

Third Party Performance Verification

Category 6

ISO/IEC Compliance

ISO/IEC 11801-1, IEC 61156-5

European Directive Compliance

EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16

UK Regulation Compliance

UKCA Mark

APAC Compliance

China RoHS II (GB/T 26572-2011)

Plenum Number

2413F / 1351A

Non-Plenum Number

2412F / 1352A

Product Notes

Notes

Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Values above 300 MHz are for Engineering Information Only. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0.

History

Update and Revision

Revision Number: 0.411 Revision Date: 12-12-2023

Part Numbers
Item # Color UPC
2149A 0101000 Black 612825379478